Đồng hồ vạn năng fluke http://donghovannang-fluke.sieuthithietbido.com Công ty Quang Minh: Nhà cung cấp Thiết bị đo và kiểm, Tự động hóa và điều khiển, Thiết bị thí nghiệm, Thiết bị điện, Dụng cụ cầm tay, Sản phẩm chính hãng, Giá tốt nhất, Liên hệ 04.38730880 - 090.400.3848 vi Sat, 05 Dec 2020 12:00:49 +0700 QuangMinh - Netvietgroup Đồng hồ vạn năng Fluke 116 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-116.html Đồng hồ vạn năng Fluke 116
Thông số kỹ thuật Đồng hồ vạn năng Fluke 116
Specifications
Maximum voltage between any terminal and earth ground
   600 V
Surge protection
   6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display
Digital:  6,000 counts, updates 4 per second
Bar graph
   33 segments, updates 32 per second
Operating Temperature
   -10 °C to + 50 °C
Storage Temperature
   -40 °C to + 60 °C
Battery type
   9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
   400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.00 V / 0.1 V
Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
Auto volts
Range:  600.0 V
Resolution:  0.1 V
Accuracy:  2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range:  600.0 mV
Resolution:  0.1 mV
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:  6.000 V / 0.001 V
Range/Resolution:  60.00 V / 0.01 V
Range/Resolution:  600.0 V / 0.1 V
Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:  600 Ω
Resolution:  1 Ω
Accuracy:  Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution:  600.0 Ω / 0.1 Ω
Range/Resolution:  6.000 kΩ / 0.001 kΩ
Range/Resolution:  60.00 kΩ / 0.01 kΩ
Range/Resolution:  600.0 kΩ / 0.1 kΩ
Range/Resolution:  6.000 MΩ / 0.001 MΩ
Accuracy:  0.9 % + 1
Range/Resolution:  40.00 MΩ / 0.01 MΩ
Accuracy:  1.5 % + 2
Diode Test
Range/Resolution:  2.000 V / 0.001 V
Accuracy:  0.9% + 2
Capacitance
Range/Resolution:  1000 nF / 1 nF
Range/Resolution:  10.00 μF / 0.01 μF
Range/Resolution:  100.0 μF / 0.1 μF
Range/Resolution:  9999 μF / 1 μF
Range/Resolution:  100 μF to 1000 μF
Accuracy:  1.9% + 2
Range/Resolution:  > 1000 μF
Accuracy:  5% + 20%
LoZ capacitance
Range:  1 nF to 500 μF
Accuracy:  10% + 2 typical
Temperature2 (Type-K thermocouple)
Range/Resolution:  -40 °C to 400 °C / 0.1 °C
Accuracy:  1% + 102
Range/Resolution:  -40 °F to 752 °F / 0.2 °F
Accuracy:  1% + 182
AC μamps true-rms (45 Hz to 500 Hz)
Range/Resolution:  600.0 μA / 0.1 μA
Accuracy:  1.0% + 2
DC μamps
Range/Resolution:  600.0 μA / 0.1 μA
Accuracy:  1.0% + 2
Hz (V or A input)2
Range/Resolution:  99.99 Hz / 0.01 Hz
Range/Resolution:  999.99 Hz / 0.1 Hz
Range/Resolution:  9.999 Hz / 0.001 Hz
Range/Resolution:  50.00 Hz / 0.01 Hz
Accuracy:  0.1% + 2
Mechanical & General Specifications
Size
   167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
Weight
   550 g

http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-116.doc
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-116.html
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-116.doc
4.350.000 VND
Đồng hồ vạn năng Fluke 116 ]]>
Mon, 27 May 2013 11:18:57 +0700 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-116.html
Đồng hồ vạn năng Fluke 88V http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-88v.html Đồng hồ vạn năng Fluke 88V
Thông số kỹ thuật Đồng hồ vạn năng Fluke 88V
Technical Specifications
DCV
Maximum Voltage:  1000V
Accuracy:  Fluke 88 V: ±(0.1%+1)
Best Resolution:  Fluke 88 V: 0.01 mV
ACV
Maximum Voltage:  1000V
Accuracy:  Fluke 88 V: ±(0.5%+2)
AC Bandwidth:  Fluke 88 V: 5kHz
Best Resolution:  0.01 mV
DC Current
Maximum Amps:  10A
Amps Accuracy:  Fluke 88 V: ±(0.4%+2)
Best Resolution:  Fluke 88 V: 0.001 mA
AC Current
Maximum Amps:  10A
Amps Accuracy:  Fluke 88 V: ±(1.2%+2)
Best Resolution:  0.001 mA
Resistance
Maximum Resistance:  50 MΩ
Accuracy:  Fluke 88 V: ±(0.4%+1)
Best Resolution:  0.1Ω
Capacitance
Maximum Capacitance:  9,999 µF
Accuracy:  ±(1%+2)
Best Resolution:  0.01 nF
Frequency
Maximum Frequency:  200 KHz
Accuracy:  ±(0.005%+1)
Best Resolution:  0.01 Hz
Duty Cycle
Maximum Duty Cycle:  99.9 %
Accuracy:  within 2% per KHz +0.1%
Best Resolution:  0.1 %
Temperature Measurement
   -200.0°C - 1090°C
   -328.0°F - 1994.0°F, 1.0% excluding probe
80 BK Temperature Probe
   -40 °C - 260 °C
   -40 °F - 500 °F, 2.2 °C or 2% whichever is greater
Conductance
Maximum Conductance:  60.00 nS
Accuracy:  ±(1.0%+10)
Maximum Resolution:  0.01 nS
Operating Range
Operating Temperature:  -20 °C - 55 °C
Storage Temperature:  -40 °C - 60 °C
Physical
   5.2 cm x 9.8cm x 20.1 cm (2.06” x 3.86” x 7.93”)
   624 g (22 oz.)

Deluxe Automotive Multimeter Includes:

  • Fluke 88V digital multimeter
  • High-impact holster
  • Test leads

Manufactủe : Fluke - USA


http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-88v.doc
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-88v.html
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-88v.doc
11.150.000 VND
Đồng hồ vạn năng Fluke 88V ]]>
Mon, 27 May 2013 11:04:52 +0700 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-88v.html
Đồng hồ vạn năng Fluke 87-V http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-87-v.html Đồng hồ vạn năng Fluke 87-V
Voltage DC
Maximum Voltage: 1000V
Accuracy: ±(0.05%+1)
Maximum Resolution: 10 µV
Voltage AC
Maximum Voltage: 1000V
Accuracy: ±(0.7%+2) True RMS
AC Bandwidth 20kHz*
*with low pass filter; 3db @ 1kHz
Maximum Resolution: 0.1 mV
Current DC
Maximum Amps: 10A (20 A for 30 seconds maximum)
Amps Accuracy: ±(0.2%+2)
Maximum Resolution: 0.01 µA
Current AC
Maximum Amps: 10A (20 A for 30 seconds maximum)
Amps Accuracy: ±(1.0%+2) True RMS
Maximum Resolution: 0.1 µA
Resistance
Maximum Resistance: 50 MΩ
Accuracy: ±(0.2%+1)
Maximum Resolution: 0.1Ω
Capacitance
Maximum Capacitance 9,999 µF
Accuracy ±(1%+2)
Maximum Resolution 0.01 nF
Frequency
Maximum Frequency 200 kHz
Accuracy ±(0.005%+1)
Maximum Resolution 0.01 Hz
Duty Cycle
Maximum Duty Cycle 99.9%
Accuracy ±(0.2% per khz +0.1%)
Maximum Resolution 0.1%
Temperature Measurement
Fluke 87 V, 87 V/E: -200.0°C - 1090°C
-328.0°F - 1994.0°F
excluding probe
80 BK Temperature Probe
-40.0°C - 260°C
-40.0°F - 500°F, 2.2°C or 2% whichever is greater
Conductance
Maximum Conductance 60.00 nS
Accuracy ±(1.0%+10)
Maximum Resolution 0.01 nS
Diode
Range: 3 V
Resolution: 1 mV
Accuracy: ± (2 % + 1)
Duty Cycle Range
Accuracy: Within ± (0.2% per kHz + 0.1 %)
Environmental Specifications
Operating Temperature -20°C to +55°C
Storage Temperature -40°C to +60°C
Humidity (Without Condensation)

0% - 90% (0°C - 35°C)
0% - 70% (35°C - 55°C)

Operating Altitude 2000 m
Safety Specifications
Overvoltage category
EN 61010-1 to 1000 V CAT III, 600V CAT IV
Agency Approvals
UL, CSA, TÜV, VDE listed
Mechanical & General Specifications
Size
201 x 98 x 52 mm (with holster)
Weight
355 g
Weigh With Holster and Flex-Stand
624 g
Display
Digital: 6000 counts updates 4/sec.
(Model 87 also has 19,999 counts in high-resolution mode.)
Analog: 32 segments, updates 40/sec.
Frequency: 19,999 counts, updates 3/sec at > 10 Hz.
Warranty
Lifetime
Battery Life
Alkaline: ~400 hours typical, without backlight
Shock
1 Meter drop per IEC 61010-1:2001
Vibration
Per MIL-PRF-28800 for a Class 2 instrument

http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-87-v.doc
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-87-v.html
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-87-v.doc
9.550.000 VND
Đồng hồ vạn năng Fluke 87-V ]]>
Tue, 25 Jun 2019 11:56:19 +0700 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-87-v.html
Đồng hồ vạn năng Fluke 114 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-114.html Đồng hồ vạn năng Fluke 114
Thông số kỹ thuật Đồng hồ vạn năng Fluke 114
Accuracy specifications
Function Range Resolution Accuracy ±
([% of Reading] + [Counts])
DC Millivolts 600.0 mV 0.1 mV 0.5 % + 2
DC Volts 6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5 % + 2
Auto-V LoZ true-rms 600.0 V 0.1 V DC, 45 Hz to 500 Hz: 2.0% + 3
500 Hz to 1 kHz: 4.0% + 3
AC millivolts true-rms 600.0 mV 0.1 mV 45 Hz to 500 Hz: 1.0% + 3
500 Hz to 1 kHz: 2.0% + 3
AC volts true-rms 6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
45 Hz to 500 Hz: 1.0% + 3
500 Hz to 1 kHz: 2.0% + 3
Continuity 600 Ω 1 Ω Beeper on < 20 W, off > 250 W;
detects opens or shorts of 500 µs or longer
Ohms 600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.9% + 2
0.9% + 1
0.9% + 1
0.9% + 1
0.9% + 1
1.5% + 2
Input characteristics
Function Input impedance 
(nominal)
Common mode rejection ratio
(1 kW unbalanced)
Normal mode rejection
Volt AC > 5 MΩ < 100 pF >60dB at dc, 50 or 60Hz -
Volts DC > 10 MΩ < 100 pF >100dB at dc, 50 or 60Hz > 60 dB at 50 or 60Hz
Auto-V LoZ ~3 kΩ < 500 pF > 60dB at dc, 50 or 60Hz -
Ohms Open circuit test voltage Full scale voltage Short circuit current
To 6.0 MΩ To 6.0 MΩ
< 2.7 V dc < 0.7 V dc < 0.9 V dc < 350 µA
Diode Test < 2.7 V dc 2.000 V dc < 1.2 mA
General specifications
Function Description
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600V CAT III, Pollution Degree 2
W Fuse for A input 11 A, 1000 V FAST 17 kA Fuse (Fluke PN 803293)
Display Digital: 6,000 counts, updates 4/sec; Bar Graph: 33 segments, updates 32/sec
Temperature Operating: -10°C to +50°C; Storage: -40°C to +60°C
Humidity 0% to 90% to 35°C
75% to 40°C
45% to 50°C
Temperature coefficient 0.1 x (specified accuracy/°C) (< 18°C or > 28°C)
Operating altitude 2,000 meters
Battery 9 Volt Alkaline, NEDA 1604A/IEC 6LR61
Battery life Alkaline: 400 hours typical, without backlight
Safety compliances ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA C22.2 No 61010-1-04, UL 6101B (2003) and IEC/EN 61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1
Certifications UL, CSA, TUV, N10140 , VDE
IP rating
(dust & water protection)
IP42

Warranty: 12 months
Manufacturer: Fluke - United States


http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-114.doc
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-114.html
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-114.doc
3.600.000 VND
Đồng hồ vạn năng Fluke 114 ]]>
Mon, 27 May 2013 11:56:36 +0700 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-114.html
Đồng hồ vạn năng Fluke 115 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-115.html Đồng hồ vạn năng Fluke 115
Thông số kỹ thuật Đồng hồ vạn năng Fluke 115
Accuracy specifications
Function Range Resolution Accuracy ±
([% of Reading] + [Counts])
DC Millivolts 600.0 mV 0.1 mV 0.5 % + 2
DC Volts 6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5 % + 2
AC millivolts
true-rms
600.0 mV 0.1 mV 45 Hz to 500 Hz: 1.0% + 3
500 Hz to 1 kHz: 2.0% + 3
AC volts
true-rms
6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
45 Hz to 500 Hz: 1.0% + 3
500 Hz to 1 kHz: 2.0% + 3
Continuity 600 Ω 1 Ω Beeper on < 20 W, off > 250 W;
detects opens or shorts of 500 µs or longer
Ohms 600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.9% + 2
0.9% + 1
0.9% + 1
0.9% + 1
0.9% + 1
1.5% + 2
Diode test 2.000 V 0.001 V 0.9 % + 2
Capacitance 1000 nF
10.00 µF
100.0 µF
9999 µF
1 nF
0.01 µF
0.1 µF
1 µF
1.9 % + 2
1.9 % + 2
1.9 % + 2
100 µF to 1000 µF: 1.9 % + 2
> 1000 µF: 5 % + 20
LoZ capacitance (power-up option) 1 nF to 500 µF 10 % + 2 typical
AC amps true-rms
(45 Hz to 500 Hz)
6.000 A
10.00 A
20 A overload for 30 seconds maximum
0.001 A
0.01 A
1.5% + 3
DC amps 6.000 A
10.00 A
20 A overload for 30 seconds maximum
0.001 A
0.01 A
1.0% + 3
Hz (V or A input) 99.99 Hz
999.9 Hz
9.999 kHz
50.00 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1% + 2
Frequency counter sensitivity
Input range Typical sensitivity (rms sine wave)
5 Hz to 45 Hz 45 Hz to 5 kHz 5 kHz to 10 kHz 10 kHz to 50 kHz
Volts AC 6 V
60 V
600 V
0.2 V
2 V
20 V
0.2V to 0.3V
2V to 3V
0V to 30V
0.3 V to 0.4 V
3 V to 4 V
30 V to 40 V
0.4 V to 1.0 V
4 V to 10 V
40 V to 100 V
AC Amps 6 A
10 A
N/A 0.4 A
0.5 A
N/A N/A
Input characteristics
Function Input impedance 
(nominal)
Common mode rejection ratio
(1 kW unbalanced)
Normal mode rejection
Volt AC > 5 MΩ < 100 pF >60dB at dc, 50 or 60Hz -
Volts DC > 10 MΩ < 100 pF >100dB at dc, 50 or 60Hz > 60 dB at 50 or 60Hz
Auto-V LoZ ~3 kΩ < 500 pF > 60dB at dc, 50 or 60Hz -
Ohms Open circuit test voltage Full scale voltage Short circuit current
To 6.0 MΩ To 6.0 MΩ
< 2.7 V dc < 0.7 V dc < 0.9 V dc < 350 µA
Diode Test < 2.7 V dc 2.000 V dc < 1.2 mA
General specifications
Function Description
Maximum voltage
between any
terminal and earth ground
600 V
Surge protection 6 kV peak per IEC 61010-1 600V CAT III, Pollution Degree 2
W Fuse for A input 11 A, 1000 V FAST 17 kA Fuse (Fluke PN 803293)
Display Digital: 6,000 counts, updates 4/sec; Bar Graph: 33 segments, updates 32/sec
Temperature Operating: -10°C to +50°C; Storage: -40°C to +60°C
Humidity 0% to 90% to 35°C
75% to 40°C
45% to 50°C
Temperature coefficient 0.1 x (specified accuracy/°C) (< 18°C or > 28°C)
Operating altitude 2,000 meters
Battery 9 Volt Alkaline, NEDA 1604A/IEC 6LR61
Battery life Alkaline: 400 hours typical, without backlight
Safety compliances ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA C22.2 No 61010-1-04, UL 6101B (2003) and IEC/EN 61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1
Certifications UL, CSA, TUV, N10140 , VDE
IP rating
(dust & water protection)
IP42

Included Accessories :
 1 - TL75 Test Lead Set
    1 - Integrated Holster
    1 - User's Manual
    1 - 9V Battery

Warranty: 12 months
Manufacturer: Fluke - United States
 


http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-115.doc
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-115.html
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-115.doc
4.450.000 VND
Đồng hồ vạn năng Fluke 115 ]]>
Mon, 27 May 2013 11:54:08 +0700 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-115.html
Đồng hồ vạn năng Fluke 117 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-117.html Đồng hồ vạn năng Fluke 117

Thông số kỹ thuật Đồng hồ vạn năng Fluke 117

Accuracy specifications
Function Range Resolution Accuracy ±
([% of Reading] + [Counts])
DC Millivolts 600.0 mV 0.1 mV 0.5 % + 2
DC Volts 6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5 % + 2
AC millivolts
true-rms
600.0 mV 0.1 mV 45 Hz to 500 Hz: 1.0% + 3
500 Hz to 1 kHz: 2.0% + 3
AC volts
true-rms
6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
45 Hz to 500 Hz: 1.0% + 3
500 Hz to 1 kHz: 2.0% + 3
Continuity 600 Ω 1 Ω Beeper on < 20 W, off > 250 W;
detects opens or shorts of 500 µs or longer
Ohms 600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.9% + 2
0.9% + 1
0.9% + 1
0.9% + 1
0.9% + 1
1.5% + 2
Diode test 2.000 V 0.001 V 0.9 % + 2
Capacitance 1000 nF
10.00 µF
100.0 µF
9999 µF
1 nF
0.01 µF
0.1 µF
1 µF
1.9 % + 2
1.9 % + 2
1.9 % + 2
100 µF to 1000 µF: 1.9 % + 2
> 1000 µF: 5 % + 20
LoZ capacitance (power-up option) 1 nF to 500 µF 10 % + 2 typical
AC amps true-rms
(45 Hz to 500 Hz)
6.000 A
10.00 A
20 A overload for 30 seconds maximum
0.001 A
0.01 A
1.5% + 3
DC amps 6.000 A
10.00 A
20 A overload for 30 seconds maximum
0.001 A
0.01 A
1.0% + 3
Hz (V or A input) 99.99 Hz
999.9 Hz
9.999 kHz
50.00 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1% + 2
Frequency counter sensitivity
Input range Typical sensitivity (rms sine wave)
5 Hz to 45 Hz 45 Hz to 5 kHz 5 kHz to 10 kHz 10 kHz to 50 kHz
Volts AC 6 V
60 V
600 V
0.2 V
2 V
20 V
0.2V to 0.3V
2V to 3V
0V to 30V
0.3 V to 0.4 V
3 V to 4 V
30 V to 40 V
0.4 V to 1.0 V
4 V to 10 V
40 V to 100 V
AC Amps 6 A
10 A
N/A 0.4 A
0.5 A
N/A N/A
Input characteristics
Function Input impedance 
(nominal)
Common mode rejection ratio
(1 kW unbalanced)
Normal mode rejection
Volt AC > 5 MΩ < 100 pF >60dB at dc, 50 or 60Hz -
Volts DC > 10 MΩ < 100 pF >100dB at dc, 50 or 60Hz > 60 dB at 50 or 60Hz
Auto-V LoZ ~3 kΩ < 500 pF > 60dB at dc, 50 or 60Hz -
Ohms Open circuit test voltage Full scale voltage Short circuit current
To 6.0 MΩ To 6.0 MΩ
< 2.7 V dc < 0.7 V dc < 0.9 V dc < 350 µA
Diode Test < 2.7 V dc 2.000 V dc < 1.2 mA
General specifications
Function Description
Maximum voltage
between any
terminal and earth ground
600 V
Surge protection 6 kV peak per IEC 61010-1 600V CAT III, Pollution Degree 2
W Fuse for A input 11 A, 1000 V FAST 17 kA Fuse (Fluke PN 803293)
Display Digital: 6,000 counts, updates 4/sec; Bar Graph: 33 segments, updates 32/sec
Temperature Operating: -10°C to +50°C; Storage: -40°C to +60°C
Humidity 0% to 90% to 35°C
75% to 40°C
45% to 50°C
Temperature coefficient 0.1 x (specified accuracy/°C) (< 18°C or > 28°C)
Operating altitude 2,000 meters
Battery 9 Volt Alkaline, NEDA 1604A/IEC 6LR61
Battery life Alkaline: 400 hours typical, without backlight
Safety compliances ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA C22.2 No 61010-1-04, UL 6101B (2003) and IEC/EN 61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1
Certifications UL, CSA, TUV, N10140 , VDE
IP rating
(dust & water protection)
IP42

Included Accessories :
1 - TL75 Test Lead Set
1 - Integrated Holster
1 - Users Manual
1 - 9V Battery
Warranty: 12 months
Manufacturer: Fluke - United States
Xuất xứ: China


http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-117.doc
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-117.html
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-117.doc
4.850.000 VND
Đồng hồ vạn năng Fluke 117 ]]>
Mon, 08 Apr 2019 15:49:36 +0700 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-117.html
Đồng hồ vạn năng FLUKE-179 EJKCT http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-179.html Đồng hồ vạn năng FLUKE-179 EJKCT
Đồng hồ vạn năng FLUKE-179
Specifications
Voltage DC
175 - Accuracy* ± (0.15%+2)
177 - Accuracy* ± (0.09%+2)
179 - Accuracy* ± (0.09%+2)
Max. Resolution 0.1 mV
Maximum 1000 V
Voltage AC
Accuracy* ± (1.0%+3)
Max. Resolution 0.1 mV
Maximum 1000 V
Current DC
Accuracy* ± (1.0%+3)
Max. Resolution 0.01 mA
Maximum 10 A
Current AC
Accuracy* ± (1.5%+3)
Max. Resolution 0.01 mA
Maximum 10 A
Resistance
Accuracy* ± (0.9%+1)
Max. Resolution 0.1 Ω
Maximum 50 MΩ
Capacitance
Accuracy* ± (1.2%+2)
Max. Resolution 1 nF
Maximum 10,000 µF
Frequency
Accuracy* ± (0.1%+1)
Max. Resolution 0.01 Hz
Maximum 100 kHz
Temperature
179 - Accuracy* ± (1.0%+10)
Max. Resolution 0.1°C
Range -40°C/400°C
Note * Accuracies are best accuracies for each function

Environmental Specifications
Operating Temperature -10°C to +50°C
Storage Temperature -30°C to +60°C
Humidity (Without Condensation)
0% - 90% (0°C - 35°C)
0% - 70% (35°C -50°C)

Safety Specifications
Overvoltage category
 EN 61010-1 to 1000 V CAT III.
 EN 61010-1 to 600 V CAT IV.
Agency Approvals UL, CSA, TÜV listed and VDE Pending

Mechanical & General Specifications
Size 43 x 90 x 185 mm
Weight 420 g
Warranty Lifetime
Battery Life Alkaline: ~200 hours typical, without backlight

Warranty: 12 months
Manufacturer: Fluke - USA


http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-179.doc
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-179.html
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-179.doc
7.850.000 VND
Đồng hồ vạn năng FLUKE-179 EJKCT ]]>
Tue, 11 Jun 2013 10:36:18 +0700 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-179.html
Đồng hồ vạn năng Fluke 17B http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-17b.html Đồng hồ vạn năng Fluke 17B

- DCV: 400mV 4V/40V/400V/1000V,+/-1.0% 
- ACV: 400mV/4V/40V/400V/1000V,+/- 3.0% 
- DCA: 400uA/4uA/40mA/400mA/4A/10A,+/- 1.5%
- ACA: 400uA/4uA/40mA/ 400mA/4A/10A, +/- 1.5%
- Ohm: 400/4K/40K/400K/4M/40M Ohm, +/- 0.5% + 3
- F: 50/500/5K/50K/100KHz, +/- 0.1%
- Temperature: -55C to 400C, 2% to 9 % +/- 2C
- C: 50nF/200nF/2uF/20uF/200uF/20mF,+/-2% +5
- Hiện thị LCD, kiểm tra liên tục, kiểm tra diode, tự động tắt nguồn
- Nguồn : 2 x AA 1.5V 
- Kích thước: 6.81 in x 2.99 in x 1.3 in
- Khối lượng : 27.83 oz
- Phụ kiện : Que đo,đầu đo nhiệt, HDSD
Bảo hành : 12 tháng
Hãng sản xuất : Fluke - USA
Xuất xứ: China


http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-17b.doc
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-17b.html
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-17b.doc
2.350.000 VND
Đồng hồ vạn năng Fluke 17B ]]>
Wed, 24 May 2017 15:26:40 +0700 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-17b.html
Bộ kit đo điện đa năng Fluke 1587/ET http://donghovannang-fluke.sieuthithietbido.com/bo-kit-do-dien-da-nang-fluke-1587-et.html Bộ kit đo điện đa năng Fluke 1587/ET
Bộ kit đo điện đa năng Fluke 1587/ET bao gồm Đồng hồ vạn năngsúng đo nhiệt độ Fluke 62
Voltage DC
Maximum Voltage 1000 V
Accuracy ±(0.09%+2)
Maximum Resolution 0.001V
Voltage AC
Maximum Voltage 1000 V
Accuracy ±(2%+3)
AC Bandwidth 5kHz with low pass filter; 3db @ 800 Hz
Maximum Resolution 0.1 mV
Current DC
Maximum Amps 400mA
Amps Accuracy ±(0.2%+2)
Maximum Resolution 0.01 mA
Current AC
Maximum Amps 400mA
Amps Accuracy ±(1.5%+2) 1kHz bandwidth
Maximum Resolution 0.01 mA
Resistance
Maximum Resistance 50 MΩ
Accuracy ±(0.9%+2)
Maximum Resolution 0.1Ω
Capacitance
Maximum Capacitance 9,999 μF
Accuracy ±(1.2%+2)
Maximum Resolution 1 nF
Frequency
Maximum Frequency 100 kHz
Accuracy ±(0.1%+1)
Maximum Resolution 0.01 Hz
Temperature Measurement -40.0 °C to 537 °C
-40.0 °F to 998 °F excluding probe
Diode Test
Range 6 V
Resolution 1 mV
Accuracy ±(2 % + 1)
Insulation Test
Minimum Test Current @ 1kΩ/V 1mA
Test Voltages 50, 100, 250, 500, 1000 V
Maximum Resistance per Test Voltage 100V: 2 GΩ
Maximum Resolution per Test Voltage 50V: 0.01 MΩ
100V: 0.01 MΩ
250V: 0.1 MΩ
500V: 0.1 MΩ
100V: 0.1 MΩ
Accuracy per Test Voltage 50V: ±(3 % + 5)
100V: ±(3 % + 5)
250V: ±(1.5 % + 5)
500V: ±(1.5 % + 5)
100V: ±(1.5 % + 5) to 600 MΩ, ±(10 % + 3) above 600 MΩ
Environmental Specifications
Operating temperature ?20 °C to +55 °C
Storage temperature -40°C to +60°C
Humidity (Without Condensation) 0% - 95% (10 °C – 30 °C)
0% - 75% (30 °C – 40 °C)
0% - 40% (40 °C – 55 °C)
Operating Altitude 2000 m
Safety Specifications
Overvoltage category Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V
Agency Approvals 2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V
Mechanical & General Specifications
Size 203 x 100 x 50 mm (with holster)
Weight 624 g
Warranty 3 years
Battery life Alkaline Meter use 1000 hours
Insulation test use Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
IP Rating IP40
Fluke i400
Nominal current range 400A
Continuous current range 1 A - 400 A
Maximum Non-Destructive Current 1000 A
Lowest measurable current 1 A
Basic accuracy 2% + 0.06 A
(45-400 Hz)
(% reading + floorspec)
Useable frequency 5 Hz - 20 kHz
Output level(s) 1 mA/A
Safety Specifications
Safety CAT IV 600 V, CAT III, 1000 V
Maximum voltage 1000 V AC rms from earth to ground, in compliance with EN61010
Mechanical & General Specifications
Warranty 1 year
Maximum conductor diameter 32 mm (1.25 inches)
Maximum conductor size (busbar) 750 MCM
Output cable length 1.5 m (59 inches)
Shrouded banana plugs Yes
Fluke 62
Backlit display for use in poorly lit areas Yes
Holds temperature readings Yes
Range -30 to 500 °C (-20° to 932 °F)
MIN/MAX/AVG MAX
Datalogging N/A
Distance to spot ratio 10:1 at 80% energy
Hi-Lo Alarm N/A
Optional RTD probe (contact temperature measurement) N/A
Emissivity Fixed at 0.95
Measurement Accuracy 10 °C to 30 °C (50 °F to 86 °F) : ± 1 °C (2 °F)
Outside 10 °C to 30 °C (50 °F to 86 °F) : ± 1.5 °C (3 °F) or ± 1.5 % of reading, whichever is greater

Includes
Fluke 1587 Insulation Multimeter
Fluke i400 AC Current Clamp
Fluke 62 Mini IR Thermometer
Rugged, utility hard case to carry everything


http://donghovannang-fluke.sieuthithietbido.com/bo-kit-do-dien-da-nang-fluke-1587-et.doc
http://donghovannang-fluke.sieuthithietbido.com/bo-kit-do-dien-da-nang-fluke-1587-et.html
http://donghovannang-fluke.sieuthithietbido.com/bo-kit-do-dien-da-nang-fluke-1587-et.doc
23.300.000 VND
Bộ kit đo điện đa năng Fluke 1587/ET ]]>
Mon, 27 May 2013 11:36:43 +0700 http://donghovannang-fluke.sieuthithietbido.com/bo-kit-do-dien-da-nang-fluke-1587-et.html
Đồng hồ vạn năng Fluke 113 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-113.html Đồng hồ vạn năng Fluke 113
Thông số kỹ thuật Đồng hồ vạn năng Fluke 113
CHECK 1,2 Range 6.000 V
60.00 V
600.0 V
Resolution 0.001 V
0.01 V
0.1 V
Accuracy DC, 45 to 500 Hz: 2.0 % + 3
500 Hz to 1 kHz: 4.0 % + 3
Diode test 3 Range 2.000 V
Resolution 0.001 V
Accuracy 2.0 % + 3
Continuity 3 Range  
Resolution  
Accuracy Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 µs or longer
Ω 3 Range 600.0 Ω
6.000 kΩ
60.00 kΩ
Resolution 0.1 Ω
0.001 kΩ
0.01 kΩ
Accuracy 0.9 % + 2
0.9 % + 1
0.9 % + 1
Capacitance 3 Range 1000 nF
10.00 µF
100.0 µF
9999 µF
Resolution 1 nF
0.01 µF
0.1 µF
1 µF
Accuracy 1.9 % + 2
1.9 % + 2
1.9 % + 2
100 µF - 1000 µF: 1.9 % + 2
> 1000 µF: 5 % + 20
Maximum voltage between any terminal and earth ground 600 V
Display 3 3/4-digits, 6000 counts, updates 4/sec
Operating temperature -10 °C to 50 °C (14 °F to 122 °F)
Storage temperature -40 °C to 60 °C (-22 °F to 140 °F)
Temperature coefficient 0.1 x (specified accuracy)/°C (< 18 °C or > 28 °C)
Operating altitude 2,000 m
Storage altitude 10,000 m
Relative humidity 95 % to 30 °C
75 % to 40 °C
45 % to 50 °C
Battery type 9 Volt Alkaline, ANSI 1604A / IEC 6F22
Battery life Alkaline: 300 hours typical, without backlight
Shock 1 Meter drop per IEC 61010-1-2001
Vibration Per MIL-PRF-28800 for Class 2 instrument
Size (H x W x L) 167.1 mm X 85.1 mm X 46.0 mm (6.58 in X 3.35 in X 1.81 in)
Weight 13.0 oz (404 g)
Safety Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No 61010-1-04, UL 61010-1 (2004) and IEC/EN 61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1
EMI regulations Complies with FCC Part 15, Class B
VCHECK Input Impedance (Nominal) ~3 kΩ < 300 pF
VCHECK Common Mode Rejection Ratio (1 kΩ Unbalanced) > 60 dB at dc, 50 or 60 Hz
Ω Open Circuit Test Voltage < 2.7 V dc
Full Scale Voltage < 0.7 V dc
Diode test Open Circuit Test Voltage < 2.7 V dc
Full Scale Voltage 2.000 V dc
Ω Short Circuit Current < 350 µA
Diode test Short Circuit Current < 1.0 mA

Manufacture : Fluke - USA


http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-113.doc
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-113.html
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-113.doc
3.400.000 VND
Đồng hồ vạn năng Fluke 113 ]]>
Mon, 27 May 2013 11:21:50 +0700 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-113.html
Đồng hồ vạn năng Fluke 175 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-175.html Đồng hồ vạn năng Fluke 175

Thông số kỹ thuật Đồng hồ vạn năng Fluke 175

Specifications
Voltage DC 175 - Accuracy* ± (0.15%+2)
Max. Resolution 0.1 mV
Maximum 1000 V
Voltage AC Accuracy* ± (1.0%+3)
Max. Resolution 0.1 mV
Maximum 1000 V
Current DC Accuracy* ± (1.0%+3)
Max. Resolution 0.01 mA
Maximum 10 A
Current AC Accuracy* ± (1.5%+3)
Max. Resolution 0.01 mA
Maximum 10 A
Resistance Accuracy* ± (0.9%+1)
Max. Resolution 0.1 Ω
Maximum 50 MΩ
Capacitance Accuracy* ± (1.2%+2)
Max. Resolution 1 nF
Maximum 10,000 µF
Frequency Accuracy* ± (0.1%+1)
Max. Resolution 0.01 Hz
Maximum 100 kHz
Temperature 179 - Accuracy* ± (1.0%+10)
Max. Resolution 0.1°C
Range -40°C/400°C
Note * Accuracies are best accuracies for each function
Environmental Specifications
Operating Temperature -10°C to +50°C
Storage Temperature -30°C to +60°C
Humidity (Without Condensation) 0% - 90% (0°C - 35°C)
0% - 70% (35°C -50°C)
Safety Specifications
Overvoltage category EN 61010-1 to 1000 V CAT III.
EN 61010-1 to 600 V CAT IV.
Agency Approvals UL, CSA, TÜV listed and VDE Pending
Mechanical & General Specifications
Size 43 x 90 x 185 mm
Weight 420 g
Warranty Lifetime
Battery Life Alkaline: ~200 hours typical, without backlight

Xuất xứ: US - Mỹ

Bảo hành 12 tháng


http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-175.doc
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-175.html
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-175.doc
6.650.000 VND
Đồng hồ vạn năng Fluke 175 ]]>
Thu, 21 Apr 2016 19:06:41 +0700 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-175.html
Đồng hồ vạn năng Fluke 177 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-177.html Đồng hồ vạn năng Fluke 177
Thông số kỹ thuật Đồng hồ vạn năng Fluke 177
C Amps Range 0.01 mA to 10.00A (20A overload for 30 seconds)
Accuracy ± (1.5% of reading plus 3 counts)
Crest Factor £3
AC Response 45 Hz to 1 kHz
DC Amps Range 0.01mA to 10.00A (20A overload for 30 seconds)
Accuracy ± (1.0% of reading plus 3 counts)
AC Volts Range 0.1 mV to 1000V
Accuracy 45 Hz to 500 Hz 1% of rdg + 3 counts, 500 Hz to 1 kHz 2% of rdg + 3 counts
AC Response 45 Hz to 1 kHz
DC Volts Range 0.1 mV to 1000V
Accuracy ± (0.09% of reading plus 2 counts)
Ohms Range 0.1W to 50.00 MW
Best Accuracy ± (0.9% of reading plus 1 count)
Capacitance Range 1 nF to 9999 µF
Best Accuracy ± (1.2% of reading plus 2 counts)
Continuity Beeper guaranteed on < 25W, guaranteed off >250W; detects opens or shorts of 250 µs or longer
Hz Range Voltage Input: 2 Hz to 100 kHz
Current Input: 2 Hz to 30 kHz
Accuracy ± (0.1% of reading plus 1 count)

http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-177.doc
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-177.html
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-177.doc
6.850.000 VND
Đồng hồ vạn năng Fluke 177 ]]>
Fri, 08 Sep 2017 15:27:26 +0700 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-177.html
Đồng hồ vạn năng Fluke 28 II Ex http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-28-ii-ex.html Đồng hồ vạn năng Fluke 28 II Ex
Hãng sản xuất: Fluke
Model: Fluke 28 II Ex
Bảo hành: 12 tháng

Điện áp DC: 0,1 mV đến 1000 V/ ±0,05 % + 1
Điện áp AC: 0,1 mV đến 1000 V/ ±0,7 % +4
Dòng điện DC: 0,1 μA đến 10 A/ ±0,2 % + 4
Dòng điện AC: 0,1 μA đến 10 A/ ±1,0 % + 2
Điện trở: 0,1 Ω đến 50 MΩ/ ±(0,2 % + 1)
Độ dẫn điện: 60,00 nS/ ± (1,0 % + 10)
Kiểm tra đi-ốt: 2,0 V/ ± (2,0 % + 1)
Chu trình hoạt động: 0,0 % đến 99,9 %/ ±(0,2 % trên kHz + 0,1 %)
Điện dung: 10 nF đến 9999 μF/ ± (1,0 % + 2)
Tần số: 0,5 Hz đến 199,99 kHz/ ± (0,005 % + 1)
Nhiệt độ: -200 °C đến +1090 °C/ ± (1,0 % + 10) °C 
Lấy giá trị đỉnh: Ghi giá trị điện áp quá độ trong chỉ 250 us
Ghi ở chế độ Tối thiểu/Tối đa/Trung bình: Tín hiệu hiển thị lên đến khoảng 100 ms

http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-28-ii-ex.doc
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-28-ii-ex.html
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-28-ii-ex.doc
34.500.000 VND
Đồng hồ vạn năng Fluke 28 II Ex ]]>
Tue, 12 Sep 2017 17:07:05 +0700 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-28-ii-ex.html
Đồng hồ vạn năng Fluke 233 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-233.html Đồng hồ vạn năng Fluke 233
Thông số kỹ thuật Đồng hồ vạn năng Fluke 233
Accuracy specifications
DC voltage
Range  0.1 mV to 1000 V
Accuracy  0.25 % + 2
AC voltage
Range  0.1 mV to 1000 V
Accuracy  1.0 % + 3
DC current
Range  1 mA to 10 A
Accuracy  1.0 % + 3
AC current
Range  1 mA to 10 A
Accuracy  1.5 % + 3
Resistance
Range  0.1 Ω to 40 MΩ
Counts
   6000
Capacitance
Range:  1 nF to 9999 μF
Resolution:  1nF
Frequency
Range:  5 Hz to 50 kHz
Resolution:  0.01Hz
Temperature
   -40 °C to +400 °C
Power
   AA batteries: Three for main body; two for display
Battery life
   400 hours
Wireless frequency
   2.4 GHz ISM Band 10 meter range
Safety rating
   CAT IV 600 V , CAT III 1000 V
General specifications
Basic features
AC true-rms  Yes
Ranging  Auto/Manual
Display
Backlight  Yes
Data storage
Min/Max/Avg  Yes
Other features
Battery type  AA alkaline
Removable display  Yes
Warranty and protection
Safety rating  CAT IV 600 V/CAT III 1000 V
External protection  Rubber overmold
Warranty  Three-years
Size (H x W x L)  5.3 cm x 9.3 cm x 19.3 cm (2.08 in x 3.6 in x 7.6 in)
Weight  604 g (1.3 Ib)
Included Accessories
 
  • 1 - Test Lead Set
  • 1 - Alligator Clip Set
  • 1 - 80BK-A Temperature Probe
  • 1 - CD-ROM
  • 1 - User's Manual
  • 5 - AA Batteries
Included

http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-233.doc
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-233.html
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-233.doc
7.300.000 VND
0 VND
Đồng hồ vạn năng Fluke 233 ]]>
Mon, 27 May 2013 11:06:41 +0700 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-233.html
Đồng hồ vạn năng Fluke 27 II http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-27-ii.html Đồng hồ vạn năng Fluke 27 II
Thông số kỹ thuật Đồng hồ vạn năng Fluke 27 II
Fluke 27II Specifications
Function Range Accuracy
DC Voltage 0.1 mV to 1000 V 0.1% +1
AC Voltage 0.1 mV to 1000 V 0.5% +3
DC Current 0.1 μA to 10 A 0.2% +4
AC Current 0.1 μA to 10 A 1.5% +4
Resistance 0.1MΩ to 50MΩ
Display counts 6000
Capacitance 1 nF to 9999 μF
Frequency 0.5 Hz to 199.99 kHz
Compliance CAT IV 600 V , CAT III 1000V
IP Rating IP 67
Power Three AA batteries
Battery life 800 hours
Physical Specifications Size 6.35 cm x 10.0 cm x 19.81 cm (with Holster)
Weight 1.54 lb (698.5 g) (with Holster)
Included Accessories
 
  • 1 - Instruction Manual
  • 1 - AA Batteries (insallted)
  • 1 - Test Leads
  • 1 - AC72 Alligator Clips
  • 1 - 16 Language User manual/Technical Note on CD-ROM
  • 1 - Holster

Manufacture : Fluke - USA


http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-27-ii.doc
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-27-ii.html
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-27-ii.doc
0 VND
Đồng hồ vạn năng Fluke 27 II ]]>
Mon, 27 May 2013 11:05:21 +0700 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-27-ii.html
Đồng hồ vạn năng Fluke 28 II http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-28-ii.html Đồng hồ vạn năng Fluke 28 II
Thông số kỹ thuật Đồng hồ vạn năng Fluke 28 II
Fluke 27II Specifications
Function Range Accuracy
DC Voltage 0.1 mV to 1000 V 0.5% +1
AC Voltage 0.1 mV to 1000 V 0.7% +3
DC Current 0.1 μA to 10 A 0.2% +4
AC Current 0.1 μA to 10 A 1.0% +2
Resistance 0.1MΩ to 50MΩ
Display counts 6000/19,999
Capacitance 1 nF to 9999 μF
Frequency 0.5 Hz to 199.99 kHz
Temperature -200 °C to +1090 °C
Compliance CAT IV 600 V , CAT III 1000V
IP Rating IP 67
Power Three AA batteries
Battery life 800 hours
Physical Specifications Size 6.35 cm x 10.0 cm x 19.81 cm (with Holster)
Weight 1.54 lb (698.5 g) (with Holster)
Included Accessories
 
  • 1 - Instruction Manual
  • 1 - AA Batteries (installed)
  • 1 - Test Leads
  • 1 - AC72 Alligator Clips
  • 1 - 80BK-A Temperature Probe
  • 1 - 16 Language User manual/Technical Note on CD-ROM
  • 1 - Holster

Manufacture : Fluke - USA


http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-28-ii.doc
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-28-ii.html
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-28-ii.doc
10.900.000 VND
Đồng hồ vạn năng Fluke 28 II ]]>
Mon, 27 May 2013 10:50:55 +0700 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-28-ii.html
Đồng hồ vạn năng Fluke 287 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-287.html Đồng hồ vạn năng Fluke 287

Thông số kỹ thuật Đồng hồ vạn năng Fluke 287

Specifications
Voltage DC
Accuracy 0.025 %
Range and Resolution 50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V
Voltage AC
Accuracy 0.4 %(true-rms)
Range and Resolution 50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V
Current DC
Accuracy 0.06 %
Range and Resolution 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Current AC
Accuracy 0.6%(true-rms)
Range and Resolution 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Temperature (excluding probe)
Accuracy 1.0 %
Range and Resolution -200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F)
Resistance
Accuracy 0.05 %
Range and Resolution 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ
Capacitance
Accuracy 1.0 %
Range and Resolution 1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF, 100.00 mF
Frequency
Accuracy 0.005% + 5
Range and Resolution 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz
Additional functions/features
Multiple on-screen displays Yes
True-rms AC bandwidth 100 kHz
DBV/dBm Yes
Conductance 50.00nS
Continuity beeper Yes
Battery/Fuse access Battery / Fuse
Peak 250 μS
Elapse time clock Yes
Time of day clock Yes
Min-Max-Avg Yes
Duty Cycle 0.01 % to 99.99 %
Pulse Width 0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms
Hold Yes
Isolated Optical Interface Yes
Auto/Touch Hold Yes
Reading memory Yes
Log to PC Yes
Interval/Event Logging Yes
Logging Memory Up to 10,000 readings
Environmental Specifications
Operating Temperature
-20 °C to +55 °C
Storage Temperature
-40 °C to +60 °C
Relative Humidity
0% to 90% (0 °C - 37 °C)
0% to 65% (37 °C - 45 °C),
0 to 45 % (45 °C - 55 °C
Electromagnetic Compatability
EMC EN6 1326-1
Vibration
Random vibration per MIL-PRF-28800f Class 2
Shock
1 meter drop per IEC/EN 61010-1 2nd edition
Mechanical & General Specifications
Maximum voltage between any terminal and earth ground
1000V
Size
(HxWxL 22.2 cm x 10.2 cm x 6 cm (8.75 in x 4.03 in x 2.38 in)
Weight
870.9 g (28 oz)
Battery Life
100 minimum, 200 hours in logging mode
Battery type
6 AA alkaline batteries, NEDA 15A IEC LR6

All models include:

  • Manual
  • 6 AA Batteries, installed
  • TL71 Silicone Test Leads
  • Probe Holder
  • Two AC72 Alligator Clips

Supplemental Material:

  • Registration Card
  • Cal Practices Document
  • CD-ROM Users Manual (16 languages)
  • Getting Started Manual
  • Statement of Calibration Practices Document

Manufature : Fluke - USA


http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-287.doc
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-287.html
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-287.doc
11.850.000 VND
Đồng hồ vạn năng Fluke 287 ]]>
Fri, 02 Aug 2019 08:52:33 +0700 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-287.html
Đồng hồ vạn năng Fluke 289 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-289.html Đồng hồ vạn năng Fluke 289

Thông số kỹ thuật Đồng hồ vạn năng Fluke 289

Specifications
Voltage DC
Accuracy 0.025 %
Range and Resolution 50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V
Voltage AC
Accuracy 0.4 %(true-rms)
Range and Resolution 50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V
Current DC
Accuracy 0.06 %
Range and Resolution 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Current AC
Accuracy 0.61 %(true-rms)
Range and Resolution 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Temperature (excluding probe)
Accuracy 1.0 %
Range and Resolution -200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F)
Resistance
Accuracy 0.05 %
Range and Resolution 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ
Resistance 10 50 Ω (2 wire connection)
Accuracy 0.15 % + 20
Range and resolution 50.000 Ω
Capacitance
Accuracy 1.0 %
Range and Resolution 1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF, 100.00 mF Ω
Frequency
Accuracy 0.005% + 5
Range and Resolution 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz
Additional functions/features
Multiple on-screen displays Yes
True-rms AC bandwidth 100 kHz
DBV/dBm Yes
DC mV resolution 1 μV
Megohm range Up to 500 M
Conductance 50.00nS
Continuity beeper Yes
Battery/Fuse access Battery / Fuse
Peak 250 μS
Elapse time clock Yes
Time of day clock Yes
Min-Max-Avg Yes
Frequency Yes
Duty Cycle 0.01 % to 99.99 %
Pulse Width 0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms
Hold Yes
Isolated Optical Interface Yes
Auto/Touch Hold Yes
Reading memory Yes
Log to PC Yes
Interval/Event Logging Yes
Logging Memory Up to 10,000 readings
Resistance Low Ohm 0.001 Ω to 50.000 Ω 10 mA source
LoZ Yes
Low Pass Filter Yes
Environmental Specifications
Operating Temperature
-20 °C to +55 °C
Storage Temperature
-40 °C to +60 °C
Relative Humidity
0% to 90% (0 °C - 37 °C)
0% to 65% (37 °C - 45 °C),
0 to 45 % (45 °C - 55 °C
Electromagnetic Compatability
EMC EN6 1326-1
Vibration
Random vibration per MIL-PRF-28800f Class 2
Shock
1 meter drop per IEC/EN 61010-1 2nd edition
Mechanical & General Specifications
Maximum voltage between any terminal and earth ground
1000V
Size
(HxWxL 22.2 cm x 10.2 cm x 6 cm (8.75 in x 4.03 in x 2.38 in)
Weight
870.9 g (28 oz)
Battery Life
100 minimum, 200 hours in logging mode
Battery type
6 AA alkaline batteries, NEDA 15A IEC LR6

Fluke 289 Includes:

  • 6 -  "AA" Batteries
  • 1 - AC72 Alligator Clips
  • 1 - TL 71 Silicon Test Lead Set
  • 1 - Users Manual

http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-289.doc
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-289.html
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-289.doc
13.700.000 VND
Đồng hồ vạn năng Fluke 289 ]]>
Wed, 11 Oct 2017 09:55:59 +0700 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-289.html
Đồng hồ vạn năng Fluke 88V/A http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-88v-a.html Đồng hồ vạn năng Fluke 88V/A
Thông số kỹ thuật Đồng hồ vạn năng Fluke 88V/A
Technical Specifications
DCV Maximum Voltage:  1000V
Accuracy:  Fluke 88 V: ±(0.1%+1)
Best Resolution:  Fluke 88 V: 0.01 mV
ACV Maximum Voltage:  1000V
Accuracy:  Fluke 88 V: ±(0.5%+2)
AC Bandwidth:  Fluke 88 V: 5kHz
Best Resolution:  0.01 mV
DC Current Maximum Amps:  10A
Amps Accuracy:  Fluke 88 V: ±(0.4%+2)
Best Resolution:  Fluke 88 V: 0.001 mA
AC Current Maximum Amps:  10A
Amps Accuracy:  Fluke 88 V: ±(1.2%+2)
Best Resolution:  0.001 mA
Resistance Maximum Resistance:  50 MΩ
Accuracy:  Fluke 88 V: ±(0.4%+1)
Best Resolution:  0.1Ω
Capacitance Maximum Capacitance:  9,999 µF
Accuracy:  ±(1%+2)
Best Resolution:  0.01 nF
Frequency Maximum Frequency:  200 KHz
Accuracy:  ±(0.005%+1)
Best Resolution:  0.01 Hz
Duty Cycle Maximum Duty Cycle:  99.9 %
Accuracy:  within 2% per KHz +0.1%
Best Resolution:  0.1 %
Temperature Measurement    -200.0°C - 1090°C
   -328.0°F - 1994.0°F, 1.0% excluding probe
80 BK Temperature Probe    -40 °C - 260 °C
   -40 °F - 500 °F, 2.2 °C or 2% whichever is greater
Conductance Maximum Conductance:  60.00 nS
Accuracy:  ±(1.0%+10)
Maximum Resolution:  0.01 nS
Operating Range Operating Temperature:  -20 °C - 55 °C
Storage Temperature:  -40 °C - 60 °C
Physical    5.2 cm x 9.8cm x 20.1 cm (2.06” x 3.86” x 7.93”)
   624 g (22 oz.)
Included Accessories 88V/A AUTOMOTIVE KIT;  88V, TL224 silicone test leads, AC285 long reach alligator clips, TP220 test probes, RPM 80 inductive RPM pick-up, magnet and strap, 80BK temperature probe, two automotive backprobe pins, insulation piercing probe, C800 durable carrying case, holster, 9V battery (installed), Getting Started Manual, and CD with detailed manual.

http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-88v-a.doc
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-88v-a.html
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-88v-a.doc
0 VND
Đồng hồ vạn năng Fluke 88V/A ]]>
Mon, 27 May 2013 10:01:59 +0700 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-88v-a.html
Đồng hồ vạn năng Fluke 289/FVF http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-289-fvf.html Đồng hồ vạn năng Fluke 289/FVF
Thông số kỹ thuật Đồng hồ vạn năng Fluke 289/FVF
DC volts 50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V @ 0.025% accuracy
AC volts 50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V @ 0.4% accuracy (true-rms)
DC current 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A @ 0.15 % accuracy
AC current 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A @ 0.7% accuracy (true-rms)
Temperature (excluding probe) -200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F) @ 1.0 % accuracy
Resistance 50.000 W (289 only), 500.00 W, 5.0000 kW, 50.000 kW, 500.00 kW, 5.0000 MW, 50.00 MW, 500.0 MW @ 0.05 % accuracy
Capacitance 1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF, 100.00 mF @ 1.0 % accuracy
Frequency 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz @ 0.005 % + 1 accuracy

Includes
Fluke 289 True-RMS Industrial Logging Multimeter with TrendCapture
Fluke 80BK-A Integrated Probe
Fluke AC72 Alligator Clips
Fluke TL71 Silicone Test Lead Set
Fluke TPAK Magnetic Meter Hanger
FlukeView Forms Software and cable
Durable and lightweight Soft Case


http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-289-fvf.doc
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-289-fvf.html
http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-289-fvf.doc
0 VND
Đồng hồ vạn năng Fluke 289/FVF ]]>
Mon, 27 May 2013 09:58:26 +0700 http://donghovannang-fluke.sieuthithietbido.com/dong-ho-van-nang-fluke-289-fvf.html